From: kyz Date: Sun, 27 Apr 2025 02:09:04 +0000 (+0800) Subject: v5.5 直通切换气体压力200改成350Kpa X-Git-Url: http://kyz.pub/gitweb/?a=commitdiff_plain;h=2a7a724fde873259bef5cd7ea08815f5d949ce7b;p=yn%2Fweldingcontroller.git v5.5 直通切换气体压力200改成350Kpa --- diff --git a/user/user.h b/user/user.h index cafe19b..679c35d 100644 --- a/user/user.h +++ b/user/user.h @@ -27,7 +27,7 @@ //#include "fmc.h" //-------------------- #define APP_VER_MAJOR 5 -#define APP_VER_MINOR 4 +#define APP_VER_MINOR 5 #define HW_V2 2 #define HW_V3 3 diff --git a/user/user_valve_ctrl.c b/user/user_valve_ctrl.c index 5f78b02..9632464 100644 --- a/user/user_valve_ctrl.c +++ b/user/user_valve_ctrl.c @@ -623,7 +623,7 @@ void user_valve_ctrl_task( void* unused ) //屏上点击旁路或温度故障,开启旁路 valve_bypass( 1 ); //旁路电磁阀开启 g_dev.valve_curr_out = 0; //比例电磁阀关闭 - }else if( g_dev.cfg.bypass == 0 && g_dev.welding_start && g_dev.pressure < 200 ){ + }else if( g_dev.cfg.bypass == 0 && g_dev.welding_start && g_dev.pressure < (200+150) ){ //2025/4/27 阈值调整200->350Kpa. // 2024/10/16 要求节气模式,气压低自动开直通,气压恢复关闭直通 // 节气 + 焊接中 + 气压低 --> 直通 valve_bypass( 1 ); //旁路电磁阀开启