float temperature;
float humidity;
+ float ctrl_internal_voltage; //controller vol
+ float ctrl_internal_current; //controller current
+
int ir;
int pos_state; // 0:init, 1:wait, 2-> OK
}rtu_bus_id_t;
int rtu_mb_init( int bus );
-int rtu_mb_connect( int bus, int addr );
-int rtu_mb_read_register( int bus, uint16_t reg_addr, uint16_t reg_nrs, uint16_t *reg_buff );
+int rtu_mb_connect( int bus );
+int rtu_mb_read_register( int bus, int8_t addr, uint16_t reg_addr, uint16_t reg_nrs, uint16_t *reg_buff );
+int rtu_mb_write_register( int bus, int8_t addr, uint16_t reg_addr, uint16_t reg_value );
//DeviceInfo
typedef struct{
return 0;
}
-int rtu_mb_connect( int bus, int addr )
+int rtu_mb_connect( int bus )
{
modbus_t *ctx;
ctx = s_mb[bus].ctx;
- // 设置Modbus主机从机地址
- modbus_set_slave(ctx, addr);
-
// 打开Modbus RTU连接
if (modbus_connect(ctx) == -1) {
fprintf(stderr, "无法连接到Modbus RTU从机: %s\n", modbus_strerror(errno));
return -1;
}
- printf( "RTU[%d] connect %d ok!\n", bus, addr );
+ printf( "RTU[%d] connect ok!\n", bus );
return 0;
}
-int rtu_mb_read_register( int bus, uint16_t reg_addr, uint16_t reg_nrs, uint16_t *reg_buff )
+int rtu_mb_read_register( int bus, int8_t addr, uint16_t reg_addr, uint16_t reg_nrs, uint16_t *reg_buff )
{
modbus_t *ctx;
if( !ctx )
return -1;
+ modbus_set_slave(ctx, addr);
+
// 读取Modbus寄存器
int rc = modbus_read_registers(ctx, reg_addr, reg_nrs, reg_buff );
if (rc == -1) {
return 0;
}
-void mb_rtu_test_read( uv_timer_t *handle )
+int rtu_mb_write_register( int bus, int8_t addr, uint16_t reg_addr, uint16_t reg_value )
{
- uint16_t buf[16];
+ modbus_t *ctx;
- if( rtu_mb_read_register( MB_RTU_BUS_2, 0, 2, buf ) == 0 ){
- AM_LOGD( "MB RTU Read reg: %04X, %04X\n", buf[0], buf[1] );
- }
-}
+ ctx = s_mb[bus].ctx;
+ if( !ctx )
+ return -1;
-uv_timer_t test_timer;
-void mb_rtu_test_init( void )
-{
- uv_timer_init( uv_default_loop(), &test_timer );
- if( rtu_mb_init( MB_RTU_BUS_2 ) == 0 ){
- if( rtu_mb_connect( MB_RTU_BUS_2, 1 ) == 0 ){
- uv_timer_start( &test_timer, mb_rtu_test_read, 5000, 3000 );
- }
+ modbus_set_slave(ctx, addr);
+
+ // 读取Modbus寄存器
+ int rc = modbus_write_register( ctx, reg_addr, reg_value );
+ if (rc == -1) {
+ return -1;
}
+ return 0;
}
int tem_sensor_fd;
int ir_dev_fd;
+
+ float ctrl_internal_voltage; //controller vol
+ float ctrl_internal_current; //controller current
+
}s_sensor;
#define BAT_ADC_PATH "/sys/bus/iio/devices/iio:device0/in_voltage6_raw"
}
extern int rtu_mb_init( int bus );
-extern int rtu_mb_connect( int bus, int addr );
-extern int rtu_mb_read_register( int bus, uint16_t reg_addr, uint16_t reg_nrs, uint16_t *reg_buff );
+
+int spk_set_channel( int ext )
+{
+ uint16_t reg_value = ext;
+ return rtu_mb_write_register( MB_RTU_BUS_2, 9, 1, reg_value );
+}
int mb_read_temperature( float *temperature, float*humidity )
{
float float_tem;
float float_hum;
- if( rtu_mb_read_register( MB_RTU_BUS_1, 0, 2, reg_data ) == 0 ){
+ if( rtu_mb_read_register( MB_RTU_BUS_1, 1, 0, 2, reg_data ) == 0 ){
//printf( "MB RTU Read reg: %04X, %04X\n", reg_data[0], reg_data[1] );
float_tem = (reg_data[0]-4000)/100.0f;
float_hum = (reg_data[1])/100.0f;
return ret;
}
+int mb_read_ctrl_info( float *voltage, float*current )
+{
+ uint16_t reg_data[2];
+ float float_vol;
+ float float_curr;
+
+ if( rtu_mb_read_register( MB_RTU_BUS_2, 1, 0, 2, reg_data ) == 0 ){
+ printf( "MB RTU BUS2 Read reg: %04X, %04X\n", reg_data[0], reg_data[1] );
+ float_vol = (reg_data[0]-4000)/100.0f;
+ float_curr = (reg_data[1])/100.0f;
+
+ if( voltage)
+ *voltage = float_vol;
+ if( current )
+ *current = float_curr;
+ //AM_LOGD( "mb_read_temperature:%.1f, humidity:%.1f", float_tem, float_hum );
+ }else{
+ //AM_LOGE( mb_read_temperature fail!" );
+ }
+ return -1;
+}
+
void iot_rpt_ir_event( void );
void sensor_read_cb( uv_work_t *req, int status )
{
g_dev.sensor_data.ac_vol[1] = s_sensor.ac_vol[1];
g_dev.sensor_data.dc_vol = s_sensor.dc_vol;
+ g_dev.sensor_data.ctrl_internal_voltage = s_sensor.ctrl_internal_voltage;
+ g_dev.sensor_data.ctrl_internal_current = s_sensor.ctrl_internal_current;
+
s_sensor.data_ready = 0;
if( g_dev.sensor_data.ir != s_sensor.ir){
AM_LOGI( "IR -> %d", s_sensor.ir);
read_ir( &s_sensor.ir );
//read_temperature( & s_sensor.tem, &s_sensor.humidity );
mb_read_temperature( & s_sensor.tem, &s_sensor.humidity );
+ mb_read_ctrl_info( & s_sensor.ctrl_internal_voltage, &s_sensor.ctrl_internal_current);
if( read_ac_info( ac_v, ac_a ) == 0 ){
s_sensor.ac_curr[0] = ac_a[0];
{
//RTU connect
if( rtu_mb_init( MB_RTU_BUS_1 ) == 0 ){
- if( rtu_mb_connect( MB_RTU_BUS_1, 1 ) == 0 ){
+ if( rtu_mb_connect( MB_RTU_BUS_1 ) == 0 ){
AM_LOGI( "RTU[%d] connect OK", MB_RTU_BUS_1 );
}else{
AM_LOGE( "RTU[%d] connect fail", MB_RTU_BUS_1 );
AM_LOGE( "RTU[%d] init fail", MB_RTU_BUS_1 );
}
+ if( rtu_mb_init( MB_RTU_BUS_2 ) == 0 ){
+ if( rtu_mb_connect( MB_RTU_BUS_2 ) == 0 ){
+ AM_LOGI( "RTU[%d] connect OK", MB_RTU_BUS_2 );
+ }else{
+ AM_LOGE( "RTU[%d] connect fail", MB_RTU_BUS_2 );
+ }
+ }else{
+ AM_LOGE( "RTU[%d] init fail", MB_RTU_BUS_2 );
+ }
+
s_sensor.tem_sensor_fd = open( TEM_SENSOR_DEV_PATH, O_RDONLY );
if( s_sensor.tem_sensor_fd < 0 )
AM_LOGE( "open tem sensor[%s] fail!", TEM_SENSOR_DEV_PATH );