modify rtu bus_2
authorkyz <kyz@kyz-vbox.myguest.virtualbox.org>
Fri, 18 Jul 2025 15:34:37 +0000 (23:34 +0800)
committerkyz <kyz@kyz-vbox.myguest.virtualbox.org>
Fri, 18 Jul 2025 15:36:25 +0000 (23:36 +0800)
app/inc/alarmmonitor.h
app/src/rtu_master.c
app/src/sensor.c

index 1de729e95107007e1f905b504897528f55540b2c..d06e43ea971aeb111fcdcbe5a0c9fadf2af570ca 100644 (file)
@@ -198,6 +198,9 @@ typedef struct{
     float temperature;
     float humidity;
 
+    float ctrl_internal_voltage; //controller vol
+    float ctrl_internal_current; //controller current
+
     int ir;
 
     int pos_state; // 0:init, 1:wait, 2-> OK
@@ -382,8 +385,9 @@ typedef enum{
 }rtu_bus_id_t;
 
 int rtu_mb_init( int bus );
-int rtu_mb_connect( int bus, int addr );
-int rtu_mb_read_register( int bus, uint16_t reg_addr, uint16_t reg_nrs, uint16_t *reg_buff );
+int rtu_mb_connect( int bus );
+int rtu_mb_read_register( int bus, int8_t addr,  uint16_t reg_addr, uint16_t reg_nrs, uint16_t *reg_buff );
+int rtu_mb_write_register( int bus, int8_t addr, uint16_t reg_addr, uint16_t reg_value );
 
 //DeviceInfo
 typedef struct{
index a405a7ea0099bec5f30955d79b32b1707c255b87..d67506e721aed333f1f8931ebd407ab22116ea15 100644 (file)
@@ -90,26 +90,23 @@ int rtu_mb_init( int bus )
     return 0;
 }
 
-int rtu_mb_connect( int bus, int addr )
+int rtu_mb_connect( int bus )
 {
     modbus_t *ctx;
 
     ctx = s_mb[bus].ctx;
 
-    // 设置Modbus主机从机地址
-    modbus_set_slave(ctx, addr);
-
     // 打开Modbus RTU连接
     if (modbus_connect(ctx) == -1) {
 
         fprintf(stderr, "无法连接到Modbus RTU从机: %s\n", modbus_strerror(errno));
         return -1;
     }
-    printf( "RTU[%d] connect %d ok!\n", bus, addr );
+    printf( "RTU[%d] connect ok!\n", bus );
     return 0;
 }
 
-int rtu_mb_read_register( int bus, uint16_t reg_addr, uint16_t reg_nrs, uint16_t *reg_buff )
+int rtu_mb_read_register( int bus, int8_t addr,  uint16_t reg_addr, uint16_t reg_nrs, uint16_t *reg_buff )
 {
     modbus_t *ctx;
 
@@ -117,6 +114,8 @@ int rtu_mb_read_register( int bus, uint16_t reg_addr, uint16_t reg_nrs, uint16_t
     if( !ctx )
         return -1;
 
+    modbus_set_slave(ctx, addr);
+
     // 读取Modbus寄存器
     int rc = modbus_read_registers(ctx, reg_addr, reg_nrs, reg_buff );
     if (rc == -1) {
@@ -129,23 +128,21 @@ int rtu_mb_read_register( int bus, uint16_t reg_addr, uint16_t reg_nrs, uint16_t
     return 0;
 }
 
-void mb_rtu_test_read( uv_timer_t *handle )
+int rtu_mb_write_register( int bus, int8_t addr, uint16_t reg_addr, uint16_t reg_value )
 {
-    uint16_t buf[16];
+    modbus_t *ctx;
 
-    if( rtu_mb_read_register( MB_RTU_BUS_2, 0, 2, buf ) == 0 ){
-        AM_LOGD( "MB RTU Read reg: %04X, %04X\n", buf[0], buf[1] );
-    }
-}
+    ctx = s_mb[bus].ctx;
+    if( !ctx )
+        return -1;
 
-uv_timer_t test_timer;
-void mb_rtu_test_init( void )
-{
-    uv_timer_init( uv_default_loop(), &test_timer );
-    if( rtu_mb_init( MB_RTU_BUS_2 ) == 0 ){
-        if( rtu_mb_connect( MB_RTU_BUS_2, 1 ) == 0 ){
-            uv_timer_start( &test_timer,  mb_rtu_test_read, 5000, 3000 );
-        }
+    modbus_set_slave(ctx, addr);
+
+    // 读取Modbus寄存器
+    int rc = modbus_write_register( ctx, reg_addr, reg_value );
+    if (rc == -1) {
+        return -1;
     }
+    return 0;
 }
 
index 03e240a6f6ad087fb8186504c167251595c424c5..b2a5fc627b794aba84cf6055263cc39a71c52bf2 100644 (file)
@@ -25,6 +25,10 @@ static struct{
 
     int tem_sensor_fd;
     int ir_dev_fd;
+
+    float ctrl_internal_voltage; //controller vol
+    float ctrl_internal_current; //controller current
+
 }s_sensor;
 
 #define BAT_ADC_PATH "/sys/bus/iio/devices/iio:device0/in_voltage6_raw"
@@ -148,8 +152,12 @@ int read_ir( int * ir )
 }
 
 extern int rtu_mb_init( int bus );
-extern int rtu_mb_connect( int bus, int addr );
-extern int rtu_mb_read_register( int bus, uint16_t reg_addr, uint16_t reg_nrs, uint16_t *reg_buff );
+
+int spk_set_channel( int ext )
+{
+    uint16_t reg_value = ext;
+    return rtu_mb_write_register( MB_RTU_BUS_2, 9, 1, reg_value );
+}
 
 int mb_read_temperature( float *temperature, float*humidity )
 {
@@ -157,7 +165,7 @@ int mb_read_temperature( float *temperature, float*humidity )
     float float_tem;
     float float_hum;
 
-    if( rtu_mb_read_register( MB_RTU_BUS_1, 0, 2, reg_data ) == 0 ){
+    if( rtu_mb_read_register( MB_RTU_BUS_1, 1, 0, 2, reg_data ) == 0 ){
         //printf( "MB RTU Read reg: %04X, %04X\n", reg_data[0], reg_data[1] );
         float_tem = (reg_data[0]-4000)/100.0f;
         float_hum = (reg_data[1])/100.0f;
@@ -228,6 +236,28 @@ int read_temperature( float *temperature, float*humidity )
     return ret;
 }
 
+int mb_read_ctrl_info( float *voltage, float*current )
+{
+    uint16_t reg_data[2];
+    float float_vol;
+    float float_curr;
+
+    if( rtu_mb_read_register( MB_RTU_BUS_2, 1, 0, 2, reg_data ) == 0 ){
+        printf( "MB RTU BUS2 Read reg: %04X, %04X\n", reg_data[0], reg_data[1] );
+        float_vol = (reg_data[0]-4000)/100.0f;
+        float_curr = (reg_data[1])/100.0f;
+
+        if( voltage)
+            *voltage = float_vol;
+        if( current )
+            *current = float_curr;
+        //AM_LOGD( "mb_read_temperature:%.1f, humidity:%.1f", float_tem, float_hum );
+    }else{
+        //AM_LOGE( mb_read_temperature fail!" );
+    }
+    return -1;
+}
+
 void iot_rpt_ir_event( void );
 void sensor_read_cb( uv_work_t *req, int status )
 {
@@ -241,6 +271,9 @@ void sensor_read_cb( uv_work_t *req, int status )
         g_dev.sensor_data.ac_vol[1] = s_sensor.ac_vol[1];
         g_dev.sensor_data.dc_vol = s_sensor.dc_vol;
 
+        g_dev.sensor_data.ctrl_internal_voltage = s_sensor.ctrl_internal_voltage;
+        g_dev.sensor_data.ctrl_internal_current = s_sensor.ctrl_internal_current;
+
         s_sensor.data_ready = 0;
         if( g_dev.sensor_data.ir != s_sensor.ir){
             AM_LOGI( "IR -> %d", s_sensor.ir);
@@ -259,6 +292,7 @@ void sensor_read( uv_work_t *req )
     read_ir( &s_sensor.ir );
     //read_temperature( & s_sensor.tem, &s_sensor.humidity );
     mb_read_temperature( & s_sensor.tem, &s_sensor.humidity );
+    mb_read_ctrl_info( & s_sensor.ctrl_internal_voltage, &s_sensor.ctrl_internal_current);
 
     if( read_ac_info( ac_v, ac_a ) == 0 ){
         s_sensor.ac_curr[0] = ac_a[0];
@@ -282,7 +316,7 @@ void device_sensor_init( am_dev_t *dev )
 {
     //RTU connect
     if( rtu_mb_init( MB_RTU_BUS_1 ) == 0 ){
-        if( rtu_mb_connect( MB_RTU_BUS_1, 1 ) == 0 ){
+        if( rtu_mb_connect( MB_RTU_BUS_1 ) == 0 ){
             AM_LOGI( "RTU[%d] connect OK", MB_RTU_BUS_1 );
         }else{
             AM_LOGE( "RTU[%d] connect fail", MB_RTU_BUS_1 );
@@ -291,6 +325,16 @@ void device_sensor_init( am_dev_t *dev )
        AM_LOGE( "RTU[%d] init fail", MB_RTU_BUS_1 );
     }
 
+    if( rtu_mb_init( MB_RTU_BUS_2 ) == 0 ){
+        if( rtu_mb_connect( MB_RTU_BUS_2 ) == 0 ){
+            AM_LOGI( "RTU[%d] connect OK", MB_RTU_BUS_2 );
+        }else{
+            AM_LOGE( "RTU[%d] connect fail", MB_RTU_BUS_2 );
+        }
+    }else{
+       AM_LOGE( "RTU[%d] init fail", MB_RTU_BUS_2 );
+    }
+
     s_sensor.tem_sensor_fd = open( TEM_SENSOR_DEV_PATH, O_RDONLY );
     if( s_sensor.tem_sensor_fd < 0 )
         AM_LOGE( "open tem sensor[%s] fail!", TEM_SENSOR_DEV_PATH );