SMC二氧化碳模式,按实际测试效果,模拟量输出改为仍按满量程50L计算
authorkyz <kongyuzhong@google.com>
Sat, 11 May 2024 02:22:20 +0000 (10:22 +0800)
committerkyz <kongyuzhong@google.com>
Sat, 11 May 2024 02:22:20 +0000 (10:22 +0800)
user/user_adc.c

index 24c9066b88776d1351444888779ff22a8c1f89e1..20ee5cdc9f85cbf9ed1f3070a33f959bee7f3185 100644 (file)
@@ -181,7 +181,8 @@ float vol_to_speed( float vol )
     }else if( g_dev.flowmeter.id == FLOWMETER_SMC ){
         //PFM750  DryAir Ar N2 量程50L/min    CO2量程  25L/min
                          if( g_dev.cfg2.gas == GAS_CO2 ){
-                                       full_speed = 25.0f; //CO2量程  25L/min
+                                       //full_speed = 25.0f; //CO2量程  25L/min
+                                       full_speed = 50.0f; //实际测试,按键切换流量计F3气体为C02后,输出模拟量仍按50满量程计算,2024/5/11
                                }else{
                                        full_speed = 50.0f; //DryAir Ar N2 量程50L/min
                                }