修改临时版本流量计算方法 tmp_v4.42_flow_28_32
authorkyz <kongyuzhong@google.com>
Fri, 22 May 2026 01:35:50 +0000 (09:35 +0800)
committerkyz <kongyuzhong@google.com>
Fri, 22 May 2026 01:35:50 +0000 (09:35 +0800)
2026/5/22 临时版
0-290A电流:气流量28L 290-350A:28-32L

user/user.h
user/user_valve_ctrl.c

index 08ecfde64aff2850a94e22ff7eb6e49e11409da5..9629cd0c0472431e480238e5d481e21eadd805b8 100644 (file)
@@ -27,7 +27,7 @@
 //#include "fmc.h"
 //--------------------
 #define APP_VER_MAJOR 4
-#define APP_VER_MINOR 4
+#define APP_VER_MINOR 42
 
 #define HW_V2  2
 #define HW_V3  3
index d5e4efadcb0acc9a90c4694bfbbb5d01073e1c22..81a73454297bc631cfab1cc7552f92570eec381e 100644 (file)
@@ -162,7 +162,7 @@ int32_t calc_target_flow( double *target_flowspeed )
             welding_current = -g_dev.welding_current;
     else
             welding_current = g_dev.welding_current;
-
+#if 0
     if( caculate( (WeldMethod)g_dev.cfg.welding_method, welding_current, g_dev.cfg.save_gas_factor, &flowspeed ) == 0 ){
         //控制流量输出, 按焊接电流和节气因子计算目标流量
                                if( flowspeed > FLOW_SPEED_FS*0.95f )
@@ -170,7 +170,20 @@ int32_t calc_target_flow( double *target_flowspeed )
         *target_flowspeed = flowspeed;
         return 0;
     }
+
     return -1;
+#else
+       //2026/5/22 临时版
+       //0-290电流气流量28L 290-350A电流大概28-32L
+       if( welding_current < 290 ){
+               *target_flowspeed = 28.0;
+       }else if( welding_current > 350 ){
+               *target_flowspeed = 32.0;
+       }else{
+               *target_flowspeed = 28.0 + (32.0-28.0)*(welding_current-290.0)/(350.0-290.0);
+       }
+       return 0;
+#endif
 }
 
 float  flowspeed_to_curr_add(  float  flowspeed )