v5.5 直通切换气体压力200改成350Kpa HW_V3
authorkyz <kongyuzhong@google.com>
Sun, 27 Apr 2025 02:09:04 +0000 (10:09 +0800)
committerkyz <kongyuzhong@google.com>
Sun, 27 Apr 2025 02:09:04 +0000 (10:09 +0800)
user/user.h
user/user_valve_ctrl.c

index cafe19b3bb42f3a6db583cf90cabe0834b5b92e4..679c35debdbfecc745c82e143f10838a210c3f30 100644 (file)
@@ -27,7 +27,7 @@
 //#include "fmc.h"
 //--------------------
 #define APP_VER_MAJOR 5
-#define APP_VER_MINOR 4
+#define APP_VER_MINOR 5
 
 #define HW_V2  2
 #define HW_V3  3
index 5f78b025f56f51b39e2221f7102b44421d15dafa..9632464fe45d2dda92b48678f79b1438cb3a6706 100644 (file)
@@ -623,7 +623,7 @@ void user_valve_ctrl_task( void* unused )
                                                                //屏上点击旁路或温度故障,开启旁路
                                                                valve_bypass( 1 );           //旁路电磁阀开启
                                                                g_dev.valve_curr_out =  0;   //比例电磁阀关闭
-                                               }else if( g_dev.cfg.bypass == 0 && g_dev.welding_start && g_dev.pressure < 200 ){
+                                               }else if( g_dev.cfg.bypass == 0 && g_dev.welding_start && g_dev.pressure < (200+150) ){ //2025/4/27 阈值调整200->350Kpa.
                                                            // 2024/10/16  要求节气模式,气压低自动开直通,气压恢复关闭直通
                                                            // 节气 + 焊接中 + 气压低 --> 直通 
                                                                valve_bypass( 1 );           //旁路电磁阀开启