projects
/
yn
/
weldingcontroller.git
/ commitdiff
commit
grep
author
committer
pickaxe
?
search:
re
summary
|
shortlog
|
log
|
commit
| commitdiff |
tree
raw
|
patch
| inline |
side by side
(parent:
14b8aa4
)
v5.5 直通切换气体压力200改成350Kpa
HW_V3
author
kyz
<kongyuzhong@google.com>
Sun, 27 Apr 2025 02:09:04 +0000
(10:09 +0800)
committer
kyz
<kongyuzhong@google.com>
Sun, 27 Apr 2025 02:09:04 +0000
(10:09 +0800)
user/user.h
patch
|
blob
|
history
user/user_valve_ctrl.c
patch
|
blob
|
history
diff --git
a/user/user.h
b/user/user.h
index cafe19b3bb42f3a6db583cf90cabe0834b5b92e4..679c35debdbfecc745c82e143f10838a210c3f30 100644
(file)
--- a/
user/user.h
+++ b/
user/user.h
@@
-27,7
+27,7
@@
//#include "fmc.h"
//--------------------
#define APP_VER_MAJOR 5
-#define APP_VER_MINOR
4
+#define APP_VER_MINOR
5
#define HW_V2 2
#define HW_V3 3
diff --git
a/user/user_valve_ctrl.c
b/user/user_valve_ctrl.c
index 5f78b025f56f51b39e2221f7102b44421d15dafa..9632464fe45d2dda92b48678f79b1438cb3a6706 100644
(file)
--- a/
user/user_valve_ctrl.c
+++ b/
user/user_valve_ctrl.c
@@
-623,7
+623,7
@@
void user_valve_ctrl_task( void* unused )
//屏上点击旁路或温度故障,开启旁路
valve_bypass( 1 ); //旁路电磁阀开启
g_dev.valve_curr_out = 0; //比例电磁阀关闭
- }else if( g_dev.cfg.bypass == 0 && g_dev.welding_start && g_dev.pressure <
200 ){
+ }else if( g_dev.cfg.bypass == 0 && g_dev.welding_start && g_dev.pressure <
(200+150) ){ //2025/4/27 阈值调整200->350Kpa.
// 2024/10/16 要求节气模式,气压低自动开直通,气压恢复关闭直通
// 节气 + 焊接中 + 气压低 --> 直通
valve_bypass( 1 ); //旁路电磁阀开启